Copyright2003© Thomas Russell Co.

Home About Us Projects Products Capabilities Shop Contact Us


Home > Project Experience > 175

Project Experience Details
 

Overview
Job Ref:  175
Type:  Cryogenic Plant
Size:  200 MMscfd
Location:  North Texas, United States
Status:  Complete

Project Description
The 200 MMSCFD cryogenic plant employs a conventional GSP liquid recovery system.  The demethanized Y-Grade product is treated for CO2 removal, yielding a product with less than 1,000 ppmw CO2.  After treating, the Y-Grade is delivered to the liquids pipeline. The residue gas is recompressed in the Expander/ Compressor and the Residue Compressor and delivered to the gas pipeline. The plant will produce about 162 MMCFD of residue gas (after fuel) and 942,000 GPD of treated Y-Grade product.  The Plant can also operate in the Ethane Rejection mode to produce a liquid product with a vapor pressure of 205 PSIG and ethane recovery of 11 percent.

Block Flow Diagram
Click on the image below to enlarge the block flow diagram for more details.
 


   Home · About Us · Personnel · Products · Project Experience · Technical Capabilities · Project Management · Shop · Links · Contact Us 
   Refining · Gas Conditioning · Gas Liquids Recovery · NGL Upgrading


   Thomas Russell Co. · 7050 South Yale Avenue, Suite 210 · Tulsa, Oklahoma · 74136 · Phone (918) 481-5682 · Fax (918) 481-7427 · Email sales@thomasrussellco.com